Automatic Smoke & Fire Curtains

firecurtains@mail.com

For a quick quote please send all of the details so that we may be able to give you a fairly accurate price, delivery and specifications.

If you require an installation within days then please phone 0116 3527223 for an immediate response as the e-mail will be answered by our office staff during normal working hours.

Quick quotes.

Opening width ?

Opening height ?

Do you require a Smoke curtain, to retain smoke only  ?

Does your Building Control Officer need a specific requirement ?

1hr or 4hr fire curtain ?

PAS 121 Insulated zone fire curtain ?

Location in building ?

Which city ?

Do you have an existing fire alarm system ?

Supply only or supply and install ?

firecurtains@mail.com

 

Smoke & Fire Curtains Limited 
Unit A, Troon Way Business Centre
Humberstone Lane
Thurmaston
Leicester. LE4 9HA
Tel 0044 (0)116 352 7223
Fax 0044 (0) 116 276 9152
 
 

                 Industrial                                          Residential
Smoke curtain / Fire Curtains / blinds /screens fire barriers
Smoke curtain / Fire Curtains / blinds /screens fire barriers
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Your Guarantees on our products and services
 
 
Let us provide you with a Quality product and Value for Money.
Along with excellent response time so make us your first call
for free Information, Quotations, sales and Installations.
 
 
150 minute insulated zone fire curtains; 150/150 
 
BS EN 1643 - 1 : 2000
Annex D PAS 121 : 2007
BS 476 : Part 20 & 22 Curtain Fire Test (Warrington Fire)
BS 476 : Part 31.1 Smoke Leakage Test  (Chiltern Fire)
BS 7346 - 6 Motor operational test in a fire (Chiltern Fire)
BS 8434 - 2 Cable resistance fire test (Chiltern Fire)
BS EN 949 : 2000 Pressure & Impact test (Chiltern Fire)
BS EN 1363 - 1 : 2000 Furnace control as stated in BSEN 1636-1:1999
BS EN 1363 - 2 Fire resistance for doors & shutters (Warrington)
BS EN 1364 - 1 Fire Test (Chiltern)
 BS EN 1364 - 1 Fire resistance test (Chiltern)
BS EN 1634 - 1 : 2000 Monitoring of air temperature (Chiltern)
BS EN 1634 - 3 : 2004 Smoke leakage at ambient temperature (Chiltern)
Warrington Middle East Certification
BS EN ISO 9001;2000 
 
 
Motors and wiring tested to run upto 300 Degrees Celsius.
Over-rides to work at 300 Degrees Celsius.
------------------------------------------------------------------------------------------
 
1hr & 4hr fire curtains.
 4hr Over-lapping curtains, to almost any width 
1hr & 4hr fire integrity. 150 minute Integrity & 150 minute "insulated zone" curtains now available
 
 
World-wide Suppliers & Installers of automatic smoke & fire curtains.
Smoke curtain / Fire Curtains / blinds /screens fire
barriers
 
 
A fire curtain, manufactured and installed by Fire Curtains Ltd, Leicester, being tested for one of our clients in London.
 
 
 This photograph is the property of Smoke & Fire Curtains Ltd

 
 
 
Insulated Zone Fire Curtains  
 
Many Building Control Officers, in London, are requesting that we use a fire curtain which has a minimum of 30 minutes integrity and also and insulating zone of 30 minutes. This is the PAS 121 standard.
During our fire tests the temperature on the safe side of the fire curtain rose only by 45 degrees Celsius, at a point 10 cm away from the curtain. This is after 30 minutes and about 1000 degrees Celsius on the fire side.
Annex D of PAS 121:2007 BRE Global
PAS 121 Impact Test
PAS 121 Smoke Test   
Cycle test of 1000 + completed to PAS 121 Specifications.
Fail Safe motors tested to work above 300 degrees Celsius.
Control panels capable of the following actions,
  1. Retract and latch emergency escape buttons set to latch for a pre-determined number of seconds
  2. Audio visual equipment optional
  3. Key switch supplied, for regular testing of fire curtains
  4. Controlled descent
  5. Wired to and from the units with fire rated cables which ensure the over-ride switches will work even if the mains supply is interupted
  6. Time delay
  7. Split drop options
  8. Sensors to warn if an object is in the opening and alert with an audio visual alarm
  9. Back up battery supply built in to the control panel. Mains supply only trickle charges the 24v batteries.
  10. Curtain will descend if the condition of the battery reduces by 20%. Optional extra.
  11. Recessed into walls and ceilings hide the fire curtains.
 
 Looking for a better price, quicker turn around time, a superior
product and an excellent service then call us on
 0116 3527223

 Corner Fire Curtains.
We are probably the only UK fire curtain manufacturing company with a fire curtain that protects
a right angled corner but WITHOUT A CORNER POST.
 Tested to BS EN 1634 - 1: 2000 at Chiltern
Fire Research Centre to 85 minutes, using a 60 minute curtain material.
 
 A result of our continual program in research and development,
searching to provide the highest standard of fire protection, using
new fire curtain technology, to provide our clients with the newest
product available but at a realistic price.


BENEFITS OF DEALING DIRECTLY WITH SMOKE & FIRE CURTAINS LTD
 
 
  1. Excellent value for money.
  2. Quick turn around time. 3 to 10 working days if urgent.
  3. Same day or instant quotations.
  4. Trade enquiries are most welcome.
  5. Units built in our factory, prepared for installation and can be installed by most general workers, with the help of our installation instructions.
  6. Our installers are all factory trained and are IPAF trained on various equipment.
  7. Nationwide supply and installation.
  8. FREE advice & specifications, just send an e-mail. 
  9. Free details on our automatic smoke or fire curtains.
  10. Controlled descent & gravity fail-safe options.
  11.  Delayed action controls & split level drops option

 
How valuable, irreplaceable or expensive are the contents of your building? We are here to help you avoid the unthinkable. No obligation, just free information. 
 
The following photographs are the property of Fire Curtains Ltd and may not be used by other companies.
Smoke & Fire Curtains / blinds
Our 4hr curtain under test.
Our fire curtains provide the benefits of an off the shelf lightweight design which eliminates the problems of steel shutters.
The fire curtain requires less preparation time and no special steelwork structure to install.
The weighted bar sags down the curtain and is inserted to test for curtains up to 8m high.
 Smoke curtain / Fire Curtains / blinds /screens fire barriers
 
 
A wide spnning Fire Curtain being installed, which involves multiple barrels.
The finished result of a multiple barrel fire curtain installation. This view from a corner.
Smoke curtain / Fire Curtains / blinds /screens fire barriers
Designed for openings of up to 30m wide by 8m high in the fire compartment wall.  It eliminates the dangers posed by heavy steel shutters which could cause fatalities.
It is especially suited to clean hygienic environments such as kitchens and hospitals, or is equally at home over windows and reception areas
The Smoke & Fire Curtains Ltd products are tested to BS476 Part 22, One hour and four hour fire curtain performance and BS7346 Part 3 for smoke.
Completing a fire curtain installation
Completing an installation in a large departmental store out of hours. Enquiry on Monday and fitted on Thursday.
 
Smoke & Fire Curtains / blinds
Portugal, A Standard 1hr Fire Curtain being installed in a Theatre.
Theatre curtains.  As shown in above picture.
  
 
Servery or hatchway fire curtains.   Made to your drawings specifications.
Not standard sizes but made to withing 5mm of your specifiactions.
Delivery 2 to 5 working days.
Slim, lightweight, easy to install and made to measure sizes.
4hr fire resistance to BS476 Part 22 and Smoke control to BS7346 Part 3
Sealed to prevent the passage of fire or smoke
24V operation with battery back-up.
Options available.
Choice of alarm actuations and fire/smoke sensors.
Powder coating in any standard RAL colour 
Gravity fail-safe motor options.
 
Automatic smoke curtains are not just an adjunct to smoke ventilation systems. They are an essential safety component, designed to protect life and help save lives, by containing and stopping the spread of lethal, superheated, noxious gases.
Fail Safe Option.
Our battery back up smoke and fire curtains are designed to close down  the openings when activated by a fire signal. These are also the option of special units which are designed to be gravity  fail safe, even without any power in the building, the back-up batteries will not only allow the curtains to fall once the required signal has been received but also in a total power failure.
Smoke curtains & fire curtains are classified by various test bodies.
Smoke Curtains.
BS 7346: Part 3  Warrington FRC, UK. BS476: Part 22, Warrington FRC, UK.
Fire Curtains.

BS 476: Part 22 Warrington Global Safety. UK.
     BS EN 1634-1: 2000 Warrington Global Safety. UK.
    WarringtonMiddle East Certification.
    BS 476: 1987 Part 8 Warrington Global Safety. UK.
    BS EN 1634-1: 2000 Chiltern Fire. Corner & Over-lapping Curtains.
    Annex D of PAS 121:2007 BRE Global.